Configuration
8 © 2007-2010 Analytica GmbH
Remote-Baudrate Baudrate of the partner device, to which a connection (bridge) is to be made
(only Bridge Modus).
Remote-Termination Terminierung of the partner device, to which a connection (bridge) is to be
made (only Bridge Modus).
The inputs will be taken over immediately after clicking the button Save settings and saved
permanently on the AnaGate CAN Gateway. A restart of the device is not necessary for activation of the
settings.
2.4. Functional extensions based on LUA
On a AnaGate CAN quattro it is possible to execute self-created applications with an installed LUA script
interpreter (see [Prog-2010] for a detailed description of all programming features).
On the page LUA LUA script files can be downloaded to the device and executed locally.