17 © 2008-2009, Analytica GmbH, D-76137 Karlsruhe, Vorholzstr. 36 18.05.2009
Chart 2-3: Browser interface: CAN settings (AnaGate CAN duo)
NOTE: The AnaGate CAN uno has only one CAN interface, the settings for port B are not
available. The AnaGate CAN quattro has to additional ports named C and D.
2.4 Firmware update
Use the “Firmware” page to load a new firmware to the AnaGate CAN Gateway. Please visit
our Web site http://www.anagate.de for further information.
2.5 Factory reset
In order to restore the default factory settings (IP address/subnet mask:
192.168.1.254/255.255.255.0), hold the RESET for approx. 10 seconds.
If the device is reset successfully, the yellow LED blinks until the RESET is released. The
default factory settings are activated immediately without a restart of the device,
NOTE: If the RESET push-button is pressed too briefly, the current IP address and network
mask is pulsed via the yellow LED (Morse code). A second push of the RESET, terminates
the pulsing, the device is not reset.