22 © 2008-2009, Analytica GmbH, D-76137 Karlsruhe, Vorholzstr. 36 18.05.2009
This line can be connected optionally to GND of the other bus devices.
In gateway mode the CAN messages are transferred transparently over TCP/IP between the
CAN network and the host platform (e.g. PC) in both directions. The AnaGate CAN Gateway
uses a unique CAN ID when sending telegrams, this ID has to be set explicitly.
All CAN messages received by the AnaGate CAN Gateway are transmitted via the API to the
host system, if the device is not requested to discard them generally. Alternatively it is
possible to set individual software filters to reduce the message transfer to the host system.
The software program CAN Monitor, which is included on the documentation CD, can be
used to monitor a CAN bus or to create single CAN telegrams.
3.2 AnaGate CAN Gateway in bridge mode
In the bridge mode two arbitrary CAN networks can be interconnected by two AnaGate CAN
Gateways. The CAN messages are exchanged transparently over TCP/IP between the two
AnaGate CAN. It is possible to mix the different AnaGate CAN Gateway models in bridge
mode.
Chart 3-2: AnaGate CAN Gateway in bridge mode