18 © 2008-2009, Analytica GmbH, D-76137 Karlsruhe, Vorholzstr. 36 18.05.2009
NOTE:
The factory reset is not possible directly after power on until complete loading of operating
system and firmware of the AnaGate. This initialization period is signalled via the yellow
activity LED. On power on the LED is switched on and after initialization the LED is switched
off.
NOTE: After the change of the IP address, the ARP cache of the personal computer has to
be deleted eventually.
2.5.1 Examining the TCP/IP settings
It is possible to check the current TCP/IP settings directly on the device..
After pressing shortly the „Reset“ button the AnaGate starts to pulse out the current TCP/IP
settings via the yellow activity LED. Pressing again the buttons stops the pulsing
immediately.
The IP address and subnet mask are pulsed out, one after the other. Following pulse codes
are used:
Digits 1, 2, 3, ...., 9: 1x, 2x, ...9x Flashing (200ms delay between each flash)
Digit 0: 10x flashing (200ms delay between each flash)
Dot: 1x very fast flash
Between two single digits a delay of 1 seconds is made, and between the IP address and
subnet mask two fast flashes are pulsed out.
Beispiel: 1 9 2 . 1 6 8 . 1 . 1
■ ■■■■■■■■■ ■■ □ ■ ■■■■■■ ■■■■■■■■ □ ■ □ ■ □□
2.6 The digital inputs and outputs
Over the 10-pole pin row on the back of the AnaGate CAN Gateway four digital inputs and
four digital outputs are led out, which can be used freely. Since the IO's are electrically
isolated from the AnaGate CAN Gateway, they must be separately supplied via the pins 1 us
2 with a voltage by 3,3V - 24V DC.